598 Series Specifications SECTION 08360 SECTIONAL DOORS 598 Series Thermacore Insulated Steel Sectional Doors PART 1 - GENERAL
1.01 RELATED DOCUMENTS A. All of the Contract Documents, including General and Supplementary Conditions, and Division 1 General Requirements, apply to the work of this Section. 1.02 SUMMARY
A. The work of this Section includes upward-acting sectional doors. B. Related Sections: Other specification sections whichdirectly relate to the work of this Section include,but are not limited to, the following:
1. Section 05500 - Miscellaneous Metal; metal framing and supports. 2. Section 08710 - Finish Hardware; key cylinders for locks. 3. Section 09900 - Painting; field painting.
4. Section 16100 - Electrical; wiring. 1.03 SUBMITTALS A. Product Data: Submit manufacturers product data and installation instructions for each type of sectional door. Include both published data and any specific
data prepared for this project. B. Shop Drawings: Submit shop drawing for approval prior to fabrication. Include detailed plans, elevations, details of framing members, required clearances, anchors, and accessories.
Include relationship with adjacent materials. 1.04. QUALITY ASSURANCE A. Manufacturer: Sectional doors shall be manufactured by a firm with a minimum of five experience in the fabrication and installation of
sectional doors. Manufacturers proposed for use, which are not named in these specifications, shall submit evidence of ability to meet performance and fabrication requirements specified, and include a list of five
projects of similar design and complexity completed within the past five years. B. Installer: Installation of sectional doors shall be performed by the authorized representative of the manufacturer. C. Single-Source
Responsibility: Provide doors, tracks, motors, and accessories from one manufacturer for each type of door. Provide secondary components from source acceptable to manufacturer of primary components. D.
Pre-Installation Conference: Schedule and convene a pre-installation conference just prior to commencement of field operations, to establish procedures to maintain optimum working conditions and to coordinate this
work with related and adjacent work. 1.05 DELIVERY, STORAGE, AND HANDLING A. Deliver materials and products in labeled protective packages. Store and handle in strict compliance with manufacturers instructions and
recommendations. Protect from damage from weather, excessive temperatures and construction operations. PART 2 - PRODUCTS 2.01 ACCEPTABLE MANUFACTURER A. Provide sectional doors
by Overhead Door Corporation, Dallas, Texas; Telephone 800-887-3667 or 972-233-6611; Fax 972-233-0367. 2.02 THERMACORE® INSULATED STEEL SECTIONAL DOORS A. Trade Reference: 598 Series Thermacore Insulated Steel
Doors by Overhead Door Corporation. B. Sectional Door Assembly: Metal/foam/metal sandwich panel construction, with ship-lap design with rounded water channels. Units shall have the following characteristics:
1. Panel Thickness: 1". 2. Exterior Surface: Ribbed, textured. 3. Exterior Steel: 0.016, hot-dipped galvanized. 4. End Stiles: 20 gauge. 5. Standard Springs: 10,000 cycles. (High cycles.)
6. Insulation: CFC-free and HCFC-free polyurethane, fully encapsulated. 7. Thermal Values: R-value of 9.34; U-value of 0.078 8. Air Infiltration: 0.08 cfm at 15 mph; 0.13 cfm at 25 mph.
9. High-Usage Package: Not required. (Required.) 10. Partial Glazing of Steel Panels: (Acrylic glazing.) (Insulated double strength glass.) (Not Required.) 11. Full Glazing Requiring Aluminum Sash
Panels: (Acrylic glazing.) (1/8 double strength glass.) (Insulated double strength glass.) (Not Required.) C. Finish and Color: Two coat baked-on polyester with white exterior and white interior
color. D. Windload Design: ANSI/NAGDM 102 standards and as required by code. E. Hardware: Galvanized steel hinges and fixtures. Ball bearing rollers with hardened steel races.
F. Lock: Interior mounted slide lock. (Tumbler keyed lock.) G. Weatherstripping: EPDM rubber tube seals fitted inside joints between sections. EPDM rubber bulb-type strip at bottom. (Header seal and jamb
weatherstripping.) H. Track: Provide track as recommended by manufacturer to suit loading required and clearances available. Note: Select type of operation I. Manual Operation: Manual pull rope. (Chain hoist.)
J. Electric Motor Operation: Provide UL listed electric operator, size and type as recommended by manufacturer to move door in either direction at not less than 2/3 foot nor more than 1 foot per second. 1. Entrapment
Protection: (Pneumatic sensing edge up to 18 wide.) (Electric sensing edge.) (Photoelectric sensors.) 2. Operation Controls: (Push-button) (Key) (Push-button and key) operated control stations with open, close, and
stop buttons for (flush) (surface) mounting, for (interior) (exterior) (both interior and exterior) location. Note: Select from below as applicable. 3. Special Operation:
(vehicle detector operation, radio control operation, card reader control, photocell operation, door timer operation, commercial light package, explosion and dust ignition proof control wiring.) PART 3 -
EXECUTION 3.01 PREPARATION A. Take field dimension and examine conditions of substrates, supports, and other conditions under which this work is to be performed. Do not proceed with work until
unsatisfactory conditions are corrected. 3.02 INSTALLATION A. Strictly comply with manufacturers installation instructions and recommendations. Coordinate installation with adjacent work to ensure proper clearances
and allow for maintenance. B. Instruct Owners personnel in proper operating procedures and maintenance schedule. 3.03 ADJUSTING AND CLEANING A. Test sectional doors for proper operation and adjust as necessary
to provide proper operation without binding or distortion. B. Touch-up damaged coatings and finishes and
repair minor damage. Clean exposed surfaces using non-abrasive
materials and methods recommended by manufacturer of material or
product being cleaned.
|