2.01 ACCEPTABLE MANUFACTURERA. Provide rolling doors by Overhead Door Corporation, Dallas, Texas; Telephone
800-887-3667 or 972-233-6611; Fax 972-233-0367.
2.02 ROLLING DOORS
A. Trade Reference: 625 Series Stormtite Insulated Service Doors by Overhead Door Corporation.
B. Curtain: Interlocking roll-formed slats as
specified following. Endlocks shall be attached to each end of alternate slats to prevent lateral movement.
1. Flat profile type F-265I for doors up to 40´0" wide. The front slat shall be fabricated of 24 gauge
galvanized steel. (22 gauge galvanized steel.) (20 gauge galvanized steel.) (18 gauge galvanized steel.) (22 gauge stainless steel.) (20 gauge stainless steel.) (Aluminum .040.) The back slat shall be 24 gauge
galvanized steel. (24 gauge stainless steel.) (Aluminum .024.)
2. Slat cavity shall be filled with CFC-free foamed-in- place, polyurethane insulation.
C. Finish:
1. Galvanized Steel: Slats and hood shall be
galvanized steel in accordance with ASTM A 525 and receive rust-inhibitive, roll coating process, including bonderizing, 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked-on polyester (powder coated) top
coat. Non-galvanized exposed ferrous surfaces shall receive one coat of rust-inhibitive primer.
2. Stainless Steel: Slats and hood shall be stainless steel with (2B mill finish) (No. 4 satin finish).
3. Aluminum:
Slats and hood shall be aluminum with (mill finish) (clear anodized finish) (bronze anodized finish).
D. Color: Gray polyester top coat. (Tan polyester top coat.) (Powder coating finish in color as selected by
Architect from manufacturers standard colors.)
E. Windload Design: 20 PSF.
F. Weatherseals: Vinyl bottom seal, exterior guide and internal hood seals. (Interior guide seals.) (Lintel seals.
G. Bottom Bar: Two
prime painted steel (galvanized steel) (stainless steel) (aluminum) angles, thickness 1/8" bolted back to back to reinforce curtain in the guides.
H. Guides: Three (galvanized) structural steel angles with minimum
thickness of 3/16". Guides shall be weatherstripped with a vinyl weather seal at each jamb, on the exterior curtain side. (and interior curtain side.)
I. Brackets: Hot rolled steel (Galvanized steel) (stainless steel)
to support counterbalance, curtain and hood.
J. Counterbalance: Helical torsion spring type designed for standard 20,000 cycle (50,000 cycle) (100,000 cycle) life design. Counterbalance shall be housed in a steel tube
or pipe barrel, supporting the curtain with deflection limited to 0.03 per foot of span. Counterbalance shall be adjustable by means of an adjusting tension wheel.
K. Hood: Galvanized steel, 24 gauge (Stainless steel,
24 gauge) (Aluminum) hood with intermediate supports as required. Provide with internal hood baffle weatherseal.
L. Manual Operation: Manual push up for doors up to 108 sq. ft. Chain hoist for doors over 108 sq. ft.
M. Electric Motor Operation: Provide UL listed electric operator, size as recommended by manufacturer to move door in either direction at not less than 2/3 foot nor more than 1 foot per second.
1. Sensing Edge Protection: (Pneumatic sensing edge.) (Electric sensing edge.)
2. Operator Controls: Push-button (Key) (Push-button and key) operated control stations with open, close, and stop buttons for surface
(flush) mounting, for interior (exterior) (both interior and exterior) location.
3. Special Operation: (Vehicle detector operation, radio control operation, card reader control, photocell operation, door timer
operation, commercial light package, explosion and dust ignition proof control wiring.)
N. Locking: Interior bottom bar slide bolt. Chain keeper locks for chain hoist operation. (Interior slide bolt lock for electric
operation with interlock switch.) (Cylinder lock for electric operation with interlock switch.)
O. Wall Mounting Condition: (Face-of-wall mounting.) (Between jambs mounting.)
P. Vision Lites: (3 x 5/8) uniformly spaced opening, open or with Plexiglas covers.
PART 3 -