Skip to Main Content
1 (800) 929-3667 (Door) Request a Quote Find a Distributor
Overhead Door
    • Garage Doors by Style
    • All Residential Garage Doors
    • Garage Door Openers
    • Garage Door Accessories
    • Wind Load Garage Doors
    • Residential Gate Operators
    • Resources

      • DoorDreamer® : View any Door on Your Home in Seconds
      • Repair My Garage Door
      • Programming Instructions
    • Commercial Product Categories
    • All Commercial Doors
    • Commercial Operators
    • Commercial Accessories
    • Loading Dock Equipment
      • Automotive
      • Family Housing
      • Food & Beverage
      • Government Facilities
      • Healthcare
      • Manufacturing
      • Parking Garage
      • Public Facilities
      • Security
      • Warehouse Solutions
    • Commercial Resources

      • Commercial Door Repair
    • Overview
    • Repair My Garage Door
    • Commercial Door Repair
    • Repair vs. Replace
    • Garage Door Opener Repair
      • Find a Distributor
    • Overview
    • Brochures
    • Warranty
    • Owners Manuals
    • Commercial Specs
    • Residential Specs
    • Dock Installation Instructions
      • DoorView - Configurator
    • Overview
    • Customize Architectural Drawings
    • BIM Object Library
    • CAD Drawings
    • Specifications
    • Additional Resources

      • Customize Architectural Drawings
      • Resources
      • Brochures
  • Home
  • About Garage Doors
  • U-factor vs R-Value

U-factor & R-value of Garage Door Insulation

Sectional Door Insulation Ratings

Understanding U-value vs. U-factor

Is U-value the same as U-factor? U-value is used differently across the building and manufacturing industry, in some instances being introduced as the reciprocal of R-value. Only U-factor is used in the building codes for door and windows. Therefore, Overhead Door™ Brand will remove all U-value listings. This will remove any confusion regarding the meaning of U-value for the residential garage and commercial door industry and further emphasize the integrity of U-factor certified ratings.


Understanding R-value

The R-value evaluates the thermal resistance of a sectional door. It represents how well the door can impede the flow of heat. The higher the R-value, the greater the insulation capability of the door. U-factor is not the reciprocal of R-value for residential garage or commercial sectional doors.


black satin glass garage door

U-factor vs. R-value

Measurement

The biggest difference between R-value and U-factor ratings is how they are measured. R-value ratings are calculated mathematically by measuring a single section of a garage or commercial sectional door. U-factor ratings, on the other hand, are calculated by measuring the whole door system installed (the entire door, siding, framing, wall, materials used, etc.). This gives a more accurate thermal transference rating and as such, a more accurate picture of the thermal insulation efficiency. 

Rating Accuracy

Another reason for the move to U-factor, is that it is difficult to accurately measure the R-value of a section of a panel that is not completely flat(flat (i.e. panels that have grooves or indentations cannot be accurately tested with R-value). U-factor gives a more accurate rating of the entire door, while R-value only measures a section of a single panel. Overhead Door Corporation Participates in the Door & Access Systems Manufacturing Association (DASMA) Thermal Performance Verification Program. The program verifies the thermal performance of residential sectional garage doors and commercial sectional doors


Overhead Door™ U-Factor & R-Value Ratings

Below is a list of our garage and commercial doors and the U-factor/R-value of each one.

Residential Garage Doors

Residential CollectionModelInsulation TypeU-factor*R-value**
​​Traditional Steel 1600Polystyrene.239.8
Durafirm Collection®3560Polyurethane.2411.75
​Thermacore®5720Polyurethane.209.31
​Thermacore® 5740Polyurethane.1512.76
WindStorm™5745Polyurethane.1512.12
Thermacore® 5760Polyurethane.1017.5
​WindStorm™5765Polyurethane.1216.22
​Impression Steel 5800Polyurethane.1512
Courtyard Collection®7520Polyurethane.209.3
Carriage House7540Polyurethane.1610
Courtyard Collection®7560Polyurethane.1512.76
WindStorm™7565Polyurethane.1512.12
Impression Fiberglass Collection®7800Polyurethane.157.6
Aluminum Full-View9920Insulated Glass.300
Aluminum Full-View9920Low E Insulated Glass.280

 

 

Commercial Doors

Commercial CollectionModelInsulation TypeU-factor*R-value**
​​Insulated Steel-Back470Polystyrene.239.83
Thermacore® Sectional Steel591Polyurethane.1314.86
Thermacore® Sectional Steel592Polyurethane.1017.5
Thermacore® Sectional Steel593Polyurethane.1512.76
Thermacore® Sectional Steel594Polyurethane.1512.76
Thermacore® Sectional Steel596Polyurethane.1017.4
Thermacore® Sectional Steel598Polyurethane.209.31
Thermacore® Sectional Steel599Polyurethane.1017.5
Thermacore® Sectional Steel850Polyurethane.0726
WindStorm™515Polyurethane.1512.12
WindStorm™525Polyurethane.1216.22
Aluminum Full View521Insulated Glass.302.6
Aluminum Full View521Low E Insulated Glass.283.43

 

*U-factor values are independently tested and verified per ANSI/DASMA 105.
**Overhead Door™ Brand uses a calculated door section R-value for our insulated doors.
sectional door thermal performance web banner

Find a Distributor

Overhead Door

1 (800) 929-3667 (DOOR)

Homeowners

  • All Residential Garage Doors
  • DoorDreamer® : View any Door on Your Home in Seconds
  • Repair My Garage Door
  • Smart Home Hub

Professionals

  • Commercial
  • Architects
  • Loading Dock Equipment
  • DoorView - Configurator

Useful links

  • About Us
  • Blogs
  • News
  • Contact Us
  • Careers
  • © 2025 Overhead Door. All rights Reserved.
  •  Legal
  •  Privacy Policy
  •  Sitemap
  • Supply Chain Ethics Policy